Real Time Continuous Water Quality Monitoring Stations.

Parameter Varthur Lake
2021-09-27 15:15:00
Bellandhur Lake
2021-09-27 15:15:00
Agara Lake
2021-09-27 15:15:00
Units Limit
pH 6.16 6.16 7.92 pH 6.5-9.0
Temperature 26.7 24.8 27.0 °C
Dissolved Ammonia 0 0.30 0.15 mg/l
COD 265.60 279.84 148.33 mg/l <50
BOD 55.40 53.97 29.67 mg/l <10
Dissolved Oxygen 0.40 0.24 0.68 mg/l
Turbidity 45.87 76.51 53.94 NTU
Conductivity 1550 1307.61 782.13 μS/cm
Chloride 155.05 156.52 18.88 mg/l
Nitrate 2.34 2.69 16.34 mg/l <10
TOC 277.46 307.82 145.64 mg/l
Level 1.11 0.31 2.22 m
PRIMARY WATER QUALITY CRITERIA
CLASS OF WATER
DESIGNED BEST USE
A Drinking Water Source without Conventional treatment but after disinfection
B Outdoor Bathing (Organized)
C Drinking Water Source after Conventional treatment and disinfection
D Propogation of Wild Life, Fisheries
E Irrigation, Industrial Cooling, Controlled waste disposal
Below-E Not meeting A,B,C,D & E Criteria