Real Time Continuous Water Quality Monitoring Stations.

Parameter Varthur Lake
2024-10-19 08:00:00
Bellandhur Lake
2024-03-27 15:45:00
Agara Lake
2024-06-04 16:59:00
Units Limit
pH 4.78 7.09 7.23 pH 6.5-9.0
Temperature 17.7 25.32 27.8 °C
Dissolved Ammonia 28.26 12.66 - mg/l
COD 319.71 249.36 46.31 mg/l <50
BOD 97.23 86.34 10.38 mg/l <10
Dissolved Oxygen 1.57 1.03 3.77 mg/l
Turbidity 23.75 54.3 - NTU
Conductivity 25.0 1426.0 - μS/cm
Chloride 265.86 109.58 - mg/l
Nitrate 31.33 22.62 - mg/l <10
TOC 340.84 358.27 - mg/l
Level 1.39 1.27 1.2 m
PRIMARY WATER QUALITY CRITERIA
CLASS OF WATER
DESIGNED BEST USE
A Drinking Water Source without Conventional treatment but after disinfection
B Outdoor Bathing (Organized)
C Drinking Water Source after Conventional treatment and disinfection
D Propogation of Wild Life, Fisheries
E Irrigation, Industrial Cooling, Controlled waste disposal
Below-E Not meeting A,B,C,D & E Criteria