Parameter |
Cauvery River
|
Krishna River
|
Unit |
---|---|---|---|
BOD | mg/l | ||
CONDUCTIVITY | 0.0 | 1044.1 | uS/cm |
TURBIDITY | NTU | ||
COD | mg/l | ||
PH | 8.1 | pH | |
DISSOLVEDOXYGEN | 5.26 | 3.03 | mg/l |
TEMPERATURE | 29.8 | C | |
CHLORIDE | 0.0 | 100.62 | mg/l |
NITRATE | 0.2 | mg/l | |
LEVEL | 0.4 | m | |
AMMONIA | 0.16 | mg/l | |
COLOR | Hazen-eq. |
Drinking water source without conventional treatment but after disinfection | A |
1. Total Coliforms Organism MPN/100ml shall be 50 or less 2. pH between 6.5 and 8.5 3. Dissolved Oxygen 6 mg/l or more 4. Biochemical Oxygen Demand 5 days 20C 2mg/l or less |
Outdoor Bathing (Organised) | B |
1. Total Coliforms Organism MPN/100ml shall be 500 or less 2. pH between 6.5 and 8.5 3. Dissolved Oxygen 5 mg/l or more 4. Biochemical Oxygen Demand 5 days 20C 3mg/l or less |
Drinking water source after conventional treatment and disinfection | C |
1. Total Coliforms Organism MPN/100ml shall be 5000 or less 2. pH between 6 to 9 3. Dissolved Oxygen 4 mg/l or more 4. Biochemical Oxygen Demand 5 days 20C 3mg/l or less |
Propagation of Wild Life & Fisheries | D |
1. pH between 6.5 and 8.5 2. Dissolved Oxygen 4 mg/l or more 3. Free Ammonia (as N) 1.2 mg/l or less |
Irrigation, Industrial Cooling, Controlled Waste Disposal | E |
1. pH between 6.0 and 8.5 2. Electrical Conductivity at 25C micro mhos/cm Max.2250 3. Sodium Absorption Ratio Max.26 4. Boron Max 2mg/l |
Below-E | Not Meeting A, B, C, D & E Criteria |